{"id":12237,"date":"2025-01-20T07:50:48","date_gmt":"2025-01-20T06:50:48","guid":{"rendered":"https:\/\/www.energycle.com\/?p=12237"},"modified":"2026-10-23T10:57:09","modified_gmt":"2026-10-23T02:57:09","slug":"industrijski-rashladni-uredaji-hladeni-zrakom","status":"publish","type":"page","link":"https:\/\/www.energycle.com\/hr\/industrijski-rashladni-uredaji-hladeni-zrakom\/","title":{"rendered":"Industrijski zra\u010dno ohla\u0111eni chilleri"},"content":{"rendered":"\n<div id=\"energycle-industrial-chiller-page\" class=\"energycle-hero-page page-id-12237\" aria-label=\"Industrial Air-Cooled Chillers for Plastic Recycling &amp; Extrusion\">\n\n    <!-- Hero Section -->\n    <section id=\"overview\" class=\"energycle-hero-section\">\n        <div class=\"energycle-hero-inner\">\n            <div class=\"energycle-hero-content\">\n                <p class=\"energycle-hero-eyebrow\">Closed-Loop Precision Temperature Control &amp; Continuous Duty<\/p>\n                <h1 class=\"energycle-hero-title\">Industrial Air-Cooled Chillers for Plastic Recycling &amp; Extrusion<\/h1>\n                <p class=\"energycle-hero-subtitle\">High-efficiency packaged air-cooled water chillers engineered for continuous 24\/7 thermal management across plastic pelletizing lines, extrusion systems, PVC pulverizers, and hydraulic power units. Featuring premium hermetic scroll compressors, intelligent microcomputer temperature stability (&plusmn;0.5&deg;C), integrated stainless steel water tanks, and environmentally compliant refrigerants without requiring external cooling towers.<\/p>\n                <div class=\"energycle-hero-actions\">\n                    <a class=\"energycle-hero-cta\" href=\"#inquiry-form\">Request a Quotation<\/a>\n                    <a class=\"energycle-hero-cta-outline\" href=\"#specifications\">Technical Specifications<\/a>\n                <\/div>\n                <nav class=\"energycle-hero-quicklinks\" aria-label=\"On-page navigation\">\n                    <a href=\"#features\" class=\"energycle-hero-quicklinks-item\">Core Features<\/a>\n                    <a href=\"#applications\" class=\"energycle-hero-quicklinks-item\">Recycling Applications<\/a>\n                    <a href=\"#workflow\" class=\"energycle-hero-quicklinks-item\">Cooling Workflow<\/a>\n                    <a href=\"#specifications\" class=\"energycle-hero-quicklinks-item\">Specifications<\/a>\n                    <a href=\"#cooling-comparison\" class=\"energycle-hero-quicklinks-item\">Comparison<\/a>\n                    <a href=\"#related-equipment\" class=\"energycle-hero-quicklinks-item\">Process Flow<\/a>\n                    <a href=\"#warranty-support\" class=\"energycle-hero-quicklinks-item\">Warranty<\/a>\n                    <a href=\"#faq\" class=\"energycle-hero-quicklinks-item\">FAQ<\/a>\n                <\/nav>\n            <\/div>\n            <div class=\"energycle-hero-image\">\n                <img class=\"energycle-hero-main-img\" src=\"https:\/\/www.energycle.com\/wp-content\/uploads\/2025\/01\/industrial-air-cooled-chillers.webp\" alt=\"Energycle Industrial Air-Cooled Chiller for Plastic Extrusion and Pelletizing Lines\" loading=\"eager\" fetchpriority=\"high\" decoding=\"async\" width=\"1440\" height=\"1080\">\n            <\/div>\n        <\/div>\n    <\/section>\n\n    <!-- Core Advantages (Bento Grid) -->\n    <section id=\"features\" class=\"energycle-advantage-section energycle-template-section\">\n        <div class=\"energycle-wrapper\">\n            <div class=\"energycle-section-header\">\n                <h2 class=\"energycle-section-title\">Engineered for Harsh Industrial Recycling Environments<\/h2>\n                <p class=\"energycle-section-desc\">Reliable process cooling protects extruder dies, prevents plastic pellet agglomeration, and stabilizes hydraulic oil under 24\/7 production demands.<\/p>\n            <\/div>\n            <div class=\"energycle-app-bento\">\n                <article class=\"energycle-app-bento-card featured energycle-scale-down\">\n                    <div class=\"energycle-app-bento-icon\"><i class=\"fa-solid fa-snowflake\" aria-hidden=\"true\"><\/i><\/div>\n                    <h3 class=\"energycle-app-bento-title\">Hermetic Scroll Compressors &amp; Dual Circuits<\/h3>\n                    <p class=\"energycle-app-bento-desc\">Utilizes globally recognized hermetic scroll or rotor compressors delivering ultra-high energy efficiency (EER &gt; 3.2), low vibration, and quiet operation. Higher-capacity models feature independent dual or quad refrigeration circuits, allowing automated staging and full redundancy so maintenance never halts your extrusion line.<\/p>\n                    <span class=\"energycle-app-bento-tag\">Zero-Downtime Redundancy<\/span>\n                <\/article>\n                <article class=\"energycle-app-bento-card energycle-scale-down\">\n                    <div class=\"energycle-app-bento-icon\"><i class=\"fa-solid fa-microchip\" aria-hidden=\"true\"><\/i><\/div>\n                    <h3 class=\"energycle-app-bento-title\">Microcomputer Precision (&plusmn;0.5&deg;C)<\/h3>\n                    <p class=\"energycle-app-bento-desc\">Smart digital PID control panel provides real-time dual temperature monitoring (inlet\/outlet) between 5&deg;C and 35&deg;C with automated diagnostic fault codes and RS485 communication for PLC integration.<\/p>\n                <\/article>\n                <article class=\"energycle-app-bento-card energycle-scale-down\">\n                    <div class=\"energycle-app-bento-icon\"><i class=\"fa-solid fa-wind\" aria-hidden=\"true\"><\/i><\/div>\n                    <h3 class=\"energycle-app-bento-title\">Tower-Free Air-Cooled Condensers<\/h3>\n                    <p class=\"energycle-app-bento-desc\">High-efficiency microchannel (MCHE) or inner-grooved copper finned condensers coupled with low-RPM axial fans reject heat directly to ambient air, completely eliminating cooling towers, water scaling, and Legionella risks.<\/p>\n                <\/article>\n                <article class=\"energycle-app-bento-card energycle-scale-down\">\n                    <div class=\"energycle-app-bento-icon\"><i class=\"fa-solid fa-water\" aria-hidden=\"true\"><\/i><\/div>\n                    <h3 class=\"energycle-app-bento-title\">Built-in SUS304 Tank &amp; Pump<\/h3>\n                    <p class=\"energycle-app-bento-desc\">Factory-integrated open stainless steel insulated reservoir (25L to 450L) with immersion coil evaporator and high-head multistage stainless circulating pump for immediate plug-and-play installation.<\/p>\n                <\/article>\n                <article class=\"energycle-app-bento-card energycle-scale-down\">\n                    <div class=\"energycle-app-bento-icon\"><i class=\"fa-solid fa-shield-halved\" aria-hidden=\"true\"><\/i><\/div>\n                    <h3 class=\"energycle-app-bento-title\">8-Point Comprehensive Protection<\/h3>\n                    <p class=\"energycle-app-bento-desc\">Equipped with compressor internal overheat cutoff, high\/low refrigerant pressure switches, 3-phase reverse phase protector, freeze prevention thermostat, and water flow level safety interlocks.<\/p>\n                <\/article>\n                <article class=\"energycle-app-bento-card energycle-app-col-span-3 energycle-scale-down\">\n                    <div class=\"energycle-app-bento-icon\"><i class=\"fa-solid fa-industry\" aria-hidden=\"true\"><\/i><\/div>\n                    <h3 class=\"energycle-app-bento-title\">Dust-Proof Enclosure for Plastic Recycling Plants<\/h3>\n                    <p class=\"energycle-app-bento-desc\">Unlike standard commercial chillers, Energycle industrial chillers are built inside heavy-gauge electro-galvanized steel cabinets with polyester powder coating. Washable quick-release air intake pre-filters prevent airborne plastic fluff, shredded dust, and fines from fouling condenser fins, ensuring sustained cooling efficiency even in dirty recycling workshop environments.<\/p>\n                <\/article>\n            <\/div>\n        <\/div>\n    <\/section>\n\n    <!-- Applications in Plastic Recycling (Standard Bento Grid) -->\n    <section id=\"applications\" class=\"energycle-template-section\">\n        <div class=\"energycle-wrapper\">\n            <div class=\"energycle-section-header\">\n                <span class=\"energycle-section-eyebrow\">Industry Applications &amp; Thermal Management<\/span>\n                <h2 class=\"energycle-section-title\">Critical Process Cooling Applications<\/h2>\n                <p class=\"energycle-section-desc\">How precision chilled water safeguards equipment performance, enhances pellet morphology, and maintains continuous throughput across plastics recycling operations.<\/p>\n            <\/div>\n            <div class=\"energycle-app-bento\">\n                <article class=\"energycle-app-bento-card featured energycle-scale-down\">\n                    <div class=\"energycle-app-bento-icon\"><i class=\"fa-solid fa-cubes-stacked\" aria-hidden=\"true\"><\/i><\/div>\n                    <h3 class=\"energycle-app-bento-title\">Water-Ring &amp; Strand Pelletizing<\/h3>\n                    <p class=\"energycle-app-bento-desc\">Delivers continuous 10&deg;C\u201315&deg;C chilled water directly to cutting water jackets and cooling flumes. Rapidly quenches molten polymer exiting extruder die heads, preventing pellet deformation, hollow centers, and cutting blade clumping.<\/p>\n                    <span class=\"energycle-app-bento-tag\">Pelletizing Quality<\/span>\n                <\/article>\n                <article class=\"energycle-app-bento-card energycle-scale-down\">\n                    <div class=\"energycle-app-bento-icon\"><i class=\"fa-solid fa-arrows-down-to-line\" aria-hidden=\"true\"><\/i><\/div>\n                    <h3 class=\"energycle-app-bento-title\">Extruder Throat &amp; Barrel Zones<\/h3>\n                    <p class=\"energycle-app-bento-desc\">Provides intensive cooling at the extruder feed throat section, preventing regrind and film fluff from prematurely softening and bridging at the hopper throat, ensuring uninterrupted infeed flow.<\/p>\n                    <span class=\"energycle-app-bento-tag\">Feed Throat Cooling<\/span>\n                <\/article>\n                <article class=\"energycle-app-bento-card energycle-scale-down\">\n                    <div class=\"energycle-app-bento-icon\"><i class=\"fa-solid fa-gears\" aria-hidden=\"true\"><\/i><\/div>\n                    <h3 class=\"energycle-app-bento-title\">PVC Micronizers &amp; Pulverizers<\/h3>\n                    <p class=\"energycle-app-bento-desc\">Absorbs friction heat from high-speed rotating grinding discs inside <a href=\"https:\/\/www.energycle.com\/plastic-granulators\/pvc-plastic-grinding-machine\/\">PVC pulverizer<\/a> chambers, preventing PVC powder from melting, decomposing, or clogging the discharge mill.<\/p>\n                    <span class=\"energycle-app-bento-tag\">Thermal Protection<\/span>\n                <\/article>\n                <article class=\"energycle-app-bento-card energycle-app-col-span-3 energycle-scale-down\">\n                    <div class=\"energycle-app-bento-icon\"><i class=\"fa-solid fa-oil-can\" aria-hidden=\"true\"><\/i><\/div>\n                    <h3 class=\"energycle-app-bento-title\">Hydraulic Power Unit Cooling for Heavy Recycling Machinery<\/h3>\n                    <p class=\"energycle-app-bento-desc\">Maintains hydraulic oil temperature below 50&deg;C on heavy-duty <a href=\"https:\/\/www.energycle.com\/industrial-balers\/\">hydraulic balers<\/a>, debalers, and guillotine cutters operating around the clock. Prevents hydraulic fluid viscosity breakdown, preserves valve seal elasticity, and eliminates pump cavitation.<\/p>\n                    <span class=\"energycle-app-bento-tag\">Oil Circuit Stability<\/span>\n                <\/article>\n            <\/div>\n        <\/div>\n    <\/section>\n\n    <!-- Process Workflow (Standard Horizontal Grid) -->\n    <section id=\"workflow\" class=\"energycle-process-section energycle-template-section\">\n        <div class=\"energycle-wrapper\">\n            <div class=\"energycle-section-header\">\n                <h2 class=\"energycle-section-title\">Closed-Loop Refrigeration Cycle<\/h2>\n                <p class=\"energycle-section-desc\">How Energycle packaged air-cooled chillers continuously maintain stable process temperatures without water loss or environmental contamination.<\/p>\n            <\/div>\n            <div class=\"energycle-process-flow-h\">\n                <div class=\"energycle-process-h-step\">\n                    <span class=\"energycle-process-h-step-num\">1<\/span>\n                    <span class=\"energycle-process-h-step-icon\"><i class=\"fa-solid fa-arrow-right-to-bracket\" aria-hidden=\"true\"><\/i><\/span>\n                    <h3 class=\"energycle-process-h-step-title\">Heat Absorption<\/h3>\n                    <p class=\"energycle-process-h-step-desc\">Warm process fluid (15&deg;C\u201325&deg;C) from pelletizer water baths or extruder throats returns to the built-in SUS304 insulated reservoir.<\/p>\n                <\/div>\n                <div class=\"energycle-process-h-step\">\n                    <span class=\"energycle-process-h-step-num\">2<\/span>\n                    <span class=\"energycle-process-h-step-icon\"><i class=\"fa-solid fa-temperature-arrow-down\" aria-hidden=\"true\"><\/i><\/span>\n                    <h3 class=\"energycle-process-h-step-title\">Refrigerant Evaporation<\/h3>\n                    <p class=\"energycle-process-h-step-desc\">High-efficiency submerged evaporator coils extract heat rapidly into the R410A\/R407C closed refrigerant circuit.<\/p>\n                <\/div>\n                <div class=\"energycle-process-h-step\">\n                    <span class=\"energycle-process-h-step-num\">3<\/span>\n                    <span class=\"energycle-process-h-step-icon\"><i class=\"fa-solid fa-fan\" aria-hidden=\"true\"><\/i><\/span>\n                    <h3 class=\"energycle-process-h-step-title\">Ambient Heat Rejection<\/h3>\n                    <p class=\"energycle-process-h-step-desc\">High-volume axial fans draw ambient air through microchannel condenser coils, rejecting thermal energy cleanly outdoors.<\/p>\n                <\/div>\n                <div class=\"energycle-process-h-step\">\n                    <span class=\"energycle-process-h-step-num\">4<\/span>\n                    <span class=\"energycle-process-h-step-icon\"><i class=\"fa-solid fa-pump-soap\" aria-hidden=\"true\"><\/i><\/span>\n                    <h3 class=\"energycle-process-h-step-title\">Precision Chilled Delivery<\/h3>\n                    <p class=\"energycle-process-h-step-desc\">Integrated stainless steel booster pump recirculates clean, temperature-regulated chilled water (5&deg;C\u201312&deg;C) back to machinery.<\/p>\n                <\/div>\n            <\/div>\n        <\/div>\n    <\/section>\n\n    <!-- Technical Specifications -->\n    <section id=\"specifications\" class=\"energycle-specs-section energycle-template-section\">\n        <div class=\"energycle-wrapper\">\n            <div class=\"energycle-section-header\">\n                <h2 class=\"energycle-section-title\">Technical Specifications &amp; Model Selection<\/h2>\n                <p class=\"energycle-section-desc\">Standard parameters for Energycle packaged industrial air-cooled chillers. Custom voltages (220V\/380V\/440V\/480V 50\/60Hz), dual pump systems, and explosion-proof designs available upon request.<\/p>\n            <\/div>\n            <div class=\"energycle-specs-table-wrapper\">\n                <table class=\"energycle-specs-table\" aria-label=\"Technical specifications for industrial air-cooled chillers\">\n                    <thead>\n                        <tr>\n                            <th>Model \/ Parameter<\/th>\n                            <th>Unit<\/th>\n                            <th>EC-AC03<\/th>\n                            <th>EC-AC05<\/th>\n                            <th>EC-AC10<\/th>\n                            <th>EC-AC15<\/th>\n                            <th>EC-AC20<\/th>\n                            <th>EC-AC30<\/th>\n                            <th>EC-AC40<\/th>\n                            <th>EC-AC50<\/th>\n                        <\/tr>\n                    <\/thead>\n                    <tbody>\n                        <tr>\n                            <td class=\"specs-model\">Nominal Cooling Capacity<\/td>\n                            <td>kW (kcal\/h)<\/td>\n                            <td>8.5 (7,310)<\/td>\n                            <td>14.2 (12,210)<\/td>\n                            <td>28.5 (24,510)<\/td>\n                            <td>45.0 (38,700)<\/td>\n                            <td>57.6 (49,530)<\/td>\n                            <td>85.0 (73,100)<\/td>\n                            <td>109.6 (94,250)<\/td>\n                            <td>180.0 (154,800)<\/td>\n                        <\/tr>\n                        <tr>\n                            <td class=\"specs-model\">Compressor Power<\/td>\n                            <td>HP (kW)<\/td>\n                            <td>3 HP (2.2)<\/td>\n                            <td>5 HP (3.75)<\/td>\n                            <td>10 HP (7.5)<\/td>\n                            <td>15 HP (11.2)<\/td>\n                            <td>20 HP (15.0)<\/td>\n                            <td>30 HP (22.5)<\/td>\n                            <td>40 HP (30.0)<\/td>\n                            <td>60 HP (45.0)<\/td>\n                        <\/tr>\n                        <tr>\n                            <td class=\"specs-model\">Compressor Type &amp; Qty<\/td>\n                            <td>&#8211;<\/td>\n                            <td colspan=\"4\">Hermetic Scroll (1 Circuit)<\/td>\n                            <td colspan=\"4\">Dual\/Quad Hermetic Scroll (Independent Circuits)<\/td>\n                        <\/tr>\n                        <tr>\n                            <td class=\"specs-model\">Total Input Power<\/td>\n                            <td>kW<\/td>\n                            <td>3.4<\/td>\n                            <td>5.1<\/td>\n                            <td>9.85<\/td>\n                            <td>15.4<\/td>\n                            <td>20.4<\/td>\n                            <td>30.6<\/td>\n                            <td>40.4<\/td>\n                            <td>59.2<\/td>\n                        <\/tr>\n                        <tr>\n                            <td class=\"specs-model\">Refrigerant Type<\/td>\n                            <td>&#8211;<\/td>\n                            <td colspan=\"8\">Eco-friendly R410A \/ R407C (R22 optional upon request)<\/td>\n                        <\/tr>\n                        <tr>\n                            <td class=\"specs-model\">Condenser Airflow<\/td>\n                            <td>m&sup3;\/h<\/td>\n                            <td>3,000<\/td>\n                            <td>5,000<\/td>\n                            <td>10,000<\/td>\n                            <td>15,000<\/td>\n                            <td>20,000<\/td>\n                            <td>30,000<\/td>\n                            <td>40,000<\/td>\n                            <td>60,000<\/td>\n                        <\/tr>\n                        <tr>\n                            <td class=\"specs-model\">Chilled Water Flow<\/td>\n                            <td>m&sup3;\/h<\/td>\n                            <td>1.5<\/td>\n                            <td>2.5<\/td>\n                            <td>4.9<\/td>\n                            <td>7.8<\/td>\n                            <td>9.9<\/td>\n                            <td>14.6<\/td>\n                            <td>18.8<\/td>\n                            <td>31.0<\/td>\n                        <\/tr>\n                        <tr>\n                            <td class=\"specs-model\">Water Tank Capacity<\/td>\n                            <td>L<\/td>\n                            <td>40<\/td>\n                            <td>60<\/td>\n                            <td>100<\/td>\n                            <td>150<\/td>\n                            <td>200<\/td>\n                            <td>300<\/td>\n                            <td>380<\/td>\n                            <td>450<\/td>\n                        <\/tr>\n                        <tr>\n                            <td class=\"specs-model\">Water Pipe Connection<\/td>\n                            <td>Inch<\/td>\n                            <td>1&quot;<\/td>\n                            <td>1&quot;<\/td>\n                            <td>1-1\/2&quot;<\/td>\n                            <td>2&quot;<\/td>\n                            <td>2&quot;<\/td>\n                            <td>2-1\/2&quot;<\/td>\n                            <td>2-1\/2&quot;<\/td>\n                            <td>3&quot;<\/td>\n                        <\/tr>\n                        <tr>\n                            <td class=\"specs-model\">Operating Weight<\/td>\n                            <td>kg<\/td>\n                            <td>150<\/td>\n                            <td>170<\/td>\n                            <td>370<\/td>\n                            <td>520<\/td>\n                            <td>790<\/td>\n                            <td>880<\/td>\n                            <td>1,100<\/td>\n                            <td>1,420<\/td>\n                        <\/tr>\n                    <\/tbody>\n                <\/table>\n            <\/div>\n            <p style=\"margin-top: 14px; font-size: 13px; color: #64748b;\">* Nominal cooling capacity measured at chilled water inlet\/outlet 15&deg;C \/ 10&deg;C, ambient temperature 35&deg;C. Performance can be optimized for low-temperature brine\/glycol solutions down to -5&deg;C.<\/p>\n        <\/div>\n    <\/section>\n\n\n    <!-- Horizontal Comparison Matrix -->\n    <section id=\"cooling-comparison\" class=\"energycle-template-section\">\n        <div class=\"energycle-wrapper\">\n            <div class=\"energycle-section-header\">\n                <span class=\"energycle-section-eyebrow\">Cooling Architecture Selection<\/span>\n                <h2 class=\"energycle-section-title\">Air-Cooled Packaged Chiller vs Cooling Tower &amp; Open Basin Systems<\/h2>\n                <p class=\"energycle-section-desc\">Selecting the right process cooling architecture balances water consumption, installation complexity, temperature stability, and winter freeze vulnerability.<\/p>\n            <\/div>\n            <div class=\"energycle-compare-table-wrap\">\n                <table class=\"energycle-compare-table\">\n                    <thead>\n                        <tr>\n                            <th>Evaluation Criteria<\/th>\n                            <th class=\"ours\">Energycle Air-Cooled Packaged Chiller<\/th>\n                            <th>Water-Cooled Chiller + Cooling Tower<\/th>\n                            <th>Direct Open Basin \/ Raw Well Cooling<\/th>\n                        <\/tr>\n                    <\/thead>\n                    <tbody>\n                        <tr>\n                            <td>System Architecture<\/td>\n                            <td>Factory-packaged closed loop; built-in stainless buffer tank and circulating pump<\/td>\n                            <td>Central chiller requiring external cooling tower, condenser pumps, and dual piping<\/td>\n                            <td>Open evaporative pond or raw groundwater pumped directly through heat exchangers<\/td>\n                        <\/tr>\n                        <tr>\n                            <td>Water Consumption &amp; Treatment<\/td>\n                            <td>Zero water consumption; closed glycol circuit prevents scaling and biological fouling<\/td>\n                            <td>High evaporative water loss; requires continuous biocides and bleed-off chemical control<\/td>\n                            <td>Massive fresh water usage; severe mineral scaling and pipeline silt accumulation<\/td>\n                        <\/tr>\n                        <tr>\n                            <td>Installation &amp; Plant Footprint<\/td>\n                            <td>Compact outdoor or rooftop skid installation; connect process fluid supply and return<\/td>\n                            <td>Large mechanical room footprint plus elevated outdoor cooling tower structure<\/td>\n                            <td>Extensive ground footprint for settling ponds, retention pits, and pump housings<\/td>\n                        <\/tr>\n                        <tr>\n                            <td>Temperature Stability &amp; Precision<\/td>\n                            <td>Microprocessor PID control maintaining setpoint within \u00b10.5\u00b0C to \u00b11.0\u00b0C<\/td>\n                            <td>Stable primary chilling, but condenser cooling capacity varies with wet-bulb humidity<\/td>\n                            <td>Wide temperature drift influenced by ambient seasonal weather and groundwater shifts<\/td>\n                        <\/tr>\n                        <tr>\n                            <td>Winter Freeze Protection<\/td>\n                            <td>Automated anti-freeze control routines, glycol compatibility, and fan speed modulation<\/td>\n                            <td>Vulnerable to tower basin freeze-up; requires basin heaters and dry-cooling bypass valves<\/td>\n                            <td>Severe freezing risk in cold climates; complex seasonal drainage and winterization<\/td>\n                        <\/tr>\n                    <\/tbody>\n                <\/table>\n            <\/div>\n        <\/div>\n    <\/section>\n\n\n    <!-- Integrated Process Flow Loop -->\n    <section id=\"related-equipment\" class=\"energycle-template-section\">\n        <div class=\"energycle-wrapper\">\n            <div class=\"energycle-section-header\">\n                <span class=\"energycle-section-eyebrow\">Integrated Recycling Line<\/span>\n                <h2 class=\"energycle-section-title\">Synchronized Process Cooling Across Your Recycling Facility<\/h2>\n                <p class=\"energycle-section-desc\">Connect the industrial chiller to high-heat recycling processes to maintain continuous production rates and protect mechanical components.<\/p>\n            <\/div>\n            <div class=\"energycle-product-grid\">\n                <a href=\"https:\/\/www.energycle.com\/double-roller-rubber-grinder\/\" class=\"energycle-product-card energycle-product-col-span-1\">\n                    <h3>Double Roller Rubber Grinder<\/h3>\n                    <p>Circulate chilled water through internal roller cooling cavities to dissipate friction heat and prevent rubber scorching.<\/p>\n                <\/a>\n                <a href=\"https:\/\/www.energycle.com\/continuous-hot-washer-system-for-pet-and-hdpe-flakes\/\" class=\"energycle-product-card energycle-product-col-span-1\">\n                    <h3>Continuous Hot Washer System<\/h3>\n                    <p>Control rinse water temperatures and cool hot flake wash streams before downstream drying and optical sorting.<\/p>\n                <\/a>\n                <a href=\"https:\/\/www.energycle.com\/lamella-clarifier\/\" class=\"energycle-product-card energycle-product-col-span-1\">\n                    <h3>Lamella Clarifier Wastewater System<\/h3>\n                    <p>Purify and settle suspended solids from industrial washing circuits prior to closed-loop chiller recirculating loops.<\/p>\n                <\/a>\n            <\/div>\n        <\/div>\n    <\/section>\n\n    <!-- Standardized 4-Card Warranty and Support -->\n    <section id=\"warranty-support\" class=\"energycle-warranty-section\">\n        <div class=\"energycle-wrapper\">\n            <div class=\"energycle-warranty-layout\">\n                <div class=\"energycle-warranty-header\">\n                    <span class=\"energycle-warranty-eyebrow\">Warranty and Support<\/span>\n                    <h2 class=\"energycle-warranty-title\">Reliable Support Throughout the Equipment Lifecycle<\/h2>\n                    <p class=\"energycle-warranty-desc\">From installation planning to routine maintenance, our service team helps keep your equipment operating safely, consistently, and efficiently.<\/p>\n                <\/div>\n                <div class=\"energycle-warranty-grid\">\n                    <article class=\"energycle-warranty-card\">\n                        <div>\n                            <h3 class=\"energycle-warranty-card-title\">1-Year Limited Warranty<\/h3>\n                            <p class=\"energycle-warranty-card-text\">Coverage includes manufacturing defects in major mechanical and electrical components for one year. Normal wear parts and damage caused by improper operation are handled separately.<\/p>\n                        <\/div>\n                        <span class=\"energycle-warranty-badge\">1-year parts and workmanship coverage<\/span>\n                    <\/article>\n                    <article class=\"energycle-warranty-card\">\n                        <div>\n                            <h3 class=\"energycle-warranty-card-title\">Installation Guidance<\/h3>\n                            <p class=\"energycle-warranty-card-text\">We provide layout, foundation, utility, clearance, line-integration, and commissioning guidance to support a smooth installation and reliable startup.<\/p>\n                        <\/div>\n                        <span class=\"energycle-warranty-badge\">Commissioning support<\/span>\n                    <\/article>\n                    <article class=\"energycle-warranty-card\">\n                        <div>\n                            <h3 class=\"energycle-warranty-card-title\">Spare Parts Supply<\/h3>\n                            <p class=\"energycle-warranty-card-text\">Replacement wear parts, bearings, seals, sensors, electrical components, and other service items are available for scheduled maintenance and long-term operation.<\/p>\n                        <\/div>\n                        <span class=\"energycle-warranty-badge\">Long-term availability<\/span>\n                    <\/article>\n                    <article class=\"energycle-warranty-card\">\n                        <div>\n                            <h3 class=\"energycle-warranty-card-title\">Technical Assistance<\/h3>\n                            <p class=\"energycle-warranty-card-text\">Remote troubleshooting, operating recommendations, maintenance guidance, and optional on-site service are available when your project needs additional support.<\/p>\n                        <\/div>\n                        <span class=\"energycle-warranty-badge\">Global service<\/span>\n                    <\/article>\n                <\/div>\n            <\/div>\n        <\/div>\n    <\/section>\n\n\n    <!-- FAQ Section (Standard Energycle Accordion) -->\n    <section id=\"faq\" class=\"energycle-faq-section energycle-template-section\">\n        <div class=\"energycle-wrapper\">\n            <div class=\"energycle-section-header\">\n                <h2 class=\"energycle-section-title\">Frequently Asked Questions<\/h2>\n                <p class=\"energycle-section-desc\">Practical engineering answers regarding chiller selection, thermal sizing, and integration with plastic recycling lines.<\/p>\n            <\/div>\n            <div class=\"energycle-faq-container\">\n                <div class=\"energycle-faq-accordion-item\">\n                    <button class=\"energycle-faq-accordion-header\" id=\"chiller-faq-q1\" aria-controls=\"chiller-faq-a1\" aria-expanded=\"false\" type=\"button\">\n                        <h3>Why are industrial chillers needed in plastic recycling and pelletizing?<\/h3>\n                        <i class=\"fa-solid fa-plus energycle-faq-accordion-icon\" aria-hidden=\"true\"><\/i>\n                    <\/button>\n                    <div class=\"energycle-faq-accordion-content\" id=\"chiller-faq-a1\" aria-labelledby=\"chiller-faq-q1\" role=\"region\" hidden=\"\">\n                        <p>Plastic recycling lines involve intense heat generation across multiple stages. In <a href=\"https:\/\/www.energycle.com\/plastic-pelletizers\/\">pelletizing systems<\/a>, molten polymer exiting the die head must be rapidly solidified in water ring pelletizers or cooling baths to achieve consistent pellet geometry and prevent clumping. Furthermore, extruder feed throat cooling prevents premature polymer melting and bridging in the hopper, while <a href=\"https:\/\/www.energycle.com\/plastic-granulators\/pvc-plastic-grinding-machine\/\">PVC pulverizers<\/a> require continuous chamber cooling to prevent thermal degradation.<\/p>\n                    <\/div>\n                <\/div>\n                <div class=\"energycle-faq-accordion-item\">\n                    <button class=\"energycle-faq-accordion-header\" id=\"chiller-faq-q2\" aria-controls=\"chiller-faq-a2\" aria-expanded=\"false\" type=\"button\">\n                        <h3>What is the advantage of an air-cooled chiller over a water-cooled chiller?<\/h3>\n                        <i class=\"fa-solid fa-plus energycle-faq-accordion-icon\" aria-hidden=\"true\"><\/i>\n                    <\/button>\n                    <div class=\"energycle-faq-accordion-content\" id=\"chiller-faq-a2\" aria-labelledby=\"chiller-faq-q2\" role=\"region\" hidden=\"\">\n                        <p>Air-cooled chillers reject heat directly to ambient air using built-in high-volume axial fans. They eliminate the need for external cooling towers, water treatment chemicals, tower circulation pumps, and makeup water supplies. This dramatically reduces installation footprint, avoids mineral scaling in hard water areas, and makes them ideal for recycling plants with restricted water availability or cold winter climates where outdoor cooling towers are prone to freezing.<\/p>\n                    <\/div>\n                <\/div>\n                <div class=\"energycle-faq-accordion-item\">\n                    <button class=\"energycle-faq-accordion-header\" id=\"chiller-faq-q3\" aria-controls=\"chiller-faq-a3\" aria-expanded=\"false\" type=\"button\">\n                        <h3>How do I size the required chiller capacity for my extrusion or recycling line?<\/h3>\n                        <i class=\"fa-solid fa-plus energycle-faq-accordion-icon\" aria-hidden=\"true\"><\/i>\n                    <\/button>\n                    <div class=\"energycle-faq-accordion-content\" id=\"chiller-faq-a3\" aria-labelledby=\"chiller-faq-q3\" role=\"region\" hidden=\"\">\n                        <p>Chiller sizing depends on the total thermal heat load of your line: Q = m &times; C<sub>p<\/sub> &times; &Delta;T, where m is the polymer output throughput per hour (kg\/h), C<sub>p<\/sub> is the specific heat capacity of the plastic (e.g., PP, PE, PET, or PVC), and &Delta;T is the temperature reduction from melt to solid state, plus additional cooling requirements for extruder feed throats and hydraulic power units. Energycle application engineers can calculate your exact BTU\/hr or kW load based on your line setup.<\/p>\n                    <\/div>\n                <\/div>\n                <div class=\"energycle-faq-accordion-item\">\n                    <button class=\"energycle-faq-accordion-header\" id=\"chiller-faq-q4\" aria-controls=\"chiller-faq-a4\" aria-expanded=\"false\" type=\"button\">\n                        <h3>Can the chiller operate with glycol for sub-zero cooling?<\/h3>\n                        <i class=\"fa-solid fa-plus energycle-faq-accordion-icon\" aria-hidden=\"true\"><\/i>\n                    <\/button>\n                    <div class=\"energycle-faq-accordion-content\" id=\"chiller-faq-a4\" aria-labelledby=\"chiller-faq-q4\" role=\"region\" hidden=\"\">\n                        <p>Yes. When cooling setpoints below 5&deg;C are required\u2014or in cold geographical regions where outdoor ambient temperatures drop below freezing\u2014the system can be charged with an ethylene or propylene glycol water solution (typically 20%\u201335% concentration). This prevents evaporator freezing and allows stable operation down to -5&deg;C to -10&deg;C fluid delivery.<\/p>\n                    <\/div>\n                <\/div>\n                <div class=\"energycle-faq-accordion-item\">\n                    <button class=\"energycle-faq-accordion-header\" id=\"chiller-faq-q5\" aria-controls=\"chiller-faq-a5\" aria-expanded=\"false\" type=\"button\">\n                        <h3>What safety interlocks protect the chiller during 24\/7 continuous operation?<\/h3>\n                        <i class=\"fa-solid fa-plus energycle-faq-accordion-icon\" aria-hidden=\"true\"><\/i>\n                    <\/button>\n                    <div class=\"energycle-faq-accordion-content\" id=\"chiller-faq-a5\" aria-labelledby=\"chiller-faq-q5\" role=\"region\" hidden=\"\">\n                        <p>Energycle packaged chillers include an 8-point automated protection matrix: compressor internal thermal overload protection, high and low refrigerant pressure cutout switches, reverse-phase and phase-loss electrical monitoring, anti-freeze thermostat safety, water flow switch cutoff, water level sensors in the reservoir, and an emergency stop circuit. All alarms display distinct error codes on the microcomputer controller for swift troubleshooting.<\/p>\n                    <\/div>\n                <\/div>\n            <\/div>\n        <\/div>\n    <\/section>\n\n    <!-- Standard Energycle 2-Column CTA & RFQ Section -->\n    <section class=\"energycle-cta-section\" id=\"inquiry-form\">\n        <div class=\"energycle-wrapper\">\n            <div class=\"energycle-cta-inner\">\n                <div class=\"energycle-cta-content\">\n                    <h2 class=\"energycle-cta-title\">Configure Your Process Cooling System<\/h2>\n                    <p class=\"energycle-cta-subtitle\">\n                        Tell us your plant throughput, polymer type (PET, PP, PE, PVC), and heat points (pelletizer water bath, extruder feed throat, hydraulic power unit). Our thermal engineers will calculate the required kW cooling capacity and provide a custom quotation.\n                    <\/p>\n                    <div class=\"energycle-cta-features\">\n                        <div class=\"energycle-cta-feature\">Precision Heat Load Sizing Calculation (Q = m &times; C<sub>p<\/sub> &times; &Delta;T)<\/div>\n                        <div class=\"energycle-cta-feature\">Plug-and-Play Packaged Units with Built-In Tank &amp; Pump<\/div>\n                        <div class=\"energycle-cta-feature\">Factory-Direct Technical Engineering &amp; Global Spare Parts<\/div>\n                    <\/div>\n                <\/div>\n                <div class=\"energycle-cta-form\">\n                    <div class='fluentform ff-default fluentform_wrapper_1 ffs_default_wrap'><form data-form_id=\"1\" id=\"fluentform_1\" class=\"frm-fluent-form fluent_form_1 ff-el-form-top ff_form_instance_1_1 ff-form-loading ffs_default\" data-form_instance=\"ff_form_instance_1_1\" method=\"POST\" data-turnstile_key=\"0x4AAAAAAC2lVxjKblyRtkwL\" ><fieldset  style=\"border: none!important;margin: 0!important;padding: 0!important;background-color: transparent!important;box-shadow: none!important;outline: none!important; min-inline-size: 100%;\">\n                    <legend class=\"ff_screen_reader_title\" style=\"display: block; margin: 0!important;padding: 0!important;height: 0!important;text-indent: -999999px;width: 0!important;overflow:hidden;\">Contact Form<\/legend><input type='hidden' name='__fluent_form_embded_post_id' value='12237' \/><input type=\"hidden\" id=\"_fluentform_1_fluentformnonce\" name=\"_fluentform_1_fluentformnonce\" value=\"118cb2777e\" \/><input type=\"hidden\" name=\"_wp_http_referer\" value=\"\/hr\/wp-json\/wp\/v2\/pages\/12237\" \/><div data-type=\"name-element\" data-name=\"names\" class=\" ff-field_container ff-name-field-wrapper\" ><div class='ff-t-container'><div class='ff-t-cell '><div class='ff-el-group'><div class=\"ff-el-input--label asterisk-right\"><label for='ff_1_names_first_name_' id='label_ff_1_names_first_name_'>First Name<\/label><\/div><div class='ff-el-input--content'><input type=\"text\" name=\"names[first_name]\" id=\"ff_1_names_first_name_\" class=\"ff-el-form-control\" placeholder=\"First Name\" aria-invalid=\"false\" aria-required=false><\/div><\/div><\/div><div class='ff-t-cell '><div class='ff-el-group'><div class=\"ff-el-input--label asterisk-right\"><label for='ff_1_names_last_name_' id='label_ff_1_names_last_name_'>Last Name<\/label><\/div><div class='ff-el-input--content'><input type=\"text\" name=\"names[last_name]\" id=\"ff_1_names_last_name_\" class=\"ff-el-form-control\" placeholder=\"Last Name\" aria-invalid=\"false\" aria-required=false><\/div><\/div><\/div><\/div><\/div><div class='ff-el-group'><div class=\"ff-el-input--label ff-el-is-required asterisk-right\"><label for='ff_1_input_text_1' id='label_ff_1_input_text_1'>Company name<\/label><\/div><div class='ff-el-input--content'><input type=\"text\" name=\"input_text_1\" class=\"ff-el-form-control\" placeholder=\"Company name\" data-name=\"input_text_1\" id=\"ff_1_input_text_1\"  aria-invalid=\"false\" aria-required=true><\/div><\/div><div class='ff-el-group'><div class=\"ff-el-input--label ff-el-is-required asterisk-right\"><label for='ff_1_email' id='label_ff_1_email'>Email<\/label><\/div><div class='ff-el-input--content'><input type=\"email\" name=\"email\" id=\"ff_1_email\" class=\"ff-el-form-control\" placeholder=\"Email Address\" data-name=\"email\"  aria-invalid=\"false\" aria-required=true><\/div><\/div><div class='ff-el-group'><div class=\"ff-el-input--label ff-el-is-required asterisk-right\"><label for='ff_1_subject' id='label_ff_1_subject'>Subject<\/label><\/div><div class='ff-el-input--content'><input type=\"text\" name=\"subject\" class=\"ff-el-form-control\" placeholder=\"Subject\" data-name=\"subject\" id=\"ff_1_subject\"  aria-invalid=\"false\" aria-required=true><\/div><\/div><div class='ff-el-group'><div class=\"ff-el-input--label ff-el-is-required asterisk-right\"><label for='ff_1_message' id='label_ff_1_message'>Your Message<\/label><\/div><div class='ff-el-input--content'><textarea aria-required=\"true\" aria-labelledby=\"label_ff_1_message\" name=\"message\" id=\"ff_1_message\" class=\"ff-el-form-control\" placeholder=\"Your Message\" rows=\"4\" cols=\"2\" data-name=\"message\" ><\/textarea><\/div><\/div><div class='ff-el-group ' ><div class='ff-el-input--content'><div data-fluent_id='1' name='cf-turnstile-response'><div\n\t\tdata-sitekey='0x4AAAAAAC2lVxjKblyRtkwL'\n\t\tdata-theme='auto'\n\t\tid='fluentform-turnstile-1-1'\n\t\tclass='ff-el-turnstile cf-turnstile'\n\t\tdata-appearance='always'><\/div><\/div><\/div><\/div><div class='ff-form-inline-style' hidden><style>form.fluent_form_1 .ff-btn-submit:not(.ff_btn_no_style) { background-color: var(--fluentform-primary); color: #ffffff; }<\/style><\/div><div class='ff-el-group ff-text-left ff_submit_btn_wrapper'><button type=\"submit\" class=\"ff-btn ff-btn-submit ff-btn-md ff_btn_style\"  aria-label=\"Submit Form\">Submit Form<\/button><\/div><\/fieldset><\/form><div id='fluentform_1_errors' class='ff-errors-in-stack ff_form_instance_1_1 ff-form-loading_errors ff_form_instance_1_1_errors'><\/div><\/div>            <script type=\"text\/javascript\">\n                window.fluent_form_ff_form_instance_1_1 = {\"id\":\"1\",\"ajaxUrl\":\"https:\\\/\\\/www.energycle.com\\\/wp-admin\\\/admin-ajax.php\",\"settings\":{\"layout\":{\"labelPlacement\":\"top\",\"helpMessagePlacement\":\"with_label\",\"errorMessagePlacement\":\"inline\",\"cssClassName\":\"\",\"asteriskPlacement\":\"asterisk-right\"},\"restrictions\":{\"denyEmptySubmission\":{\"enabled\":false}}},\"form_instance\":\"ff_form_instance_1_1\",\"form_id_selector\":\"fluentform_1\",\"rules\":{\"names[first_name]\":{\"required\":{\"value\":false,\"message\":\"This field is required\",\"global\":false,\"global_message\":\"This field is required\"}},\"names[middle_name]\":{\"required\":{\"value\":false,\"message\":\"This field is required\",\"global\":false,\"global_message\":\"This field is required\"}},\"names[last_name]\":{\"required\":{\"value\":false,\"message\":\"This field is required\",\"global\":false,\"global_message\":\"This field is required\"}},\"input_text_1\":{\"required\":{\"value\":true,\"message\":\"This field is required\",\"global_message\":\"This field is required\",\"global\":true}},\"email\":{\"required\":{\"value\":true,\"message\":\"This field is required\",\"global\":false,\"global_message\":\"This field is required\"},\"email\":{\"value\":true,\"message\":\"This field must contain a valid email\",\"global\":false,\"global_message\":\"This field must contain a valid email\"}},\"subject\":{\"required\":{\"value\":true,\"message\":\"This field is required\",\"global\":false,\"global_message\":\"This field is required\"}},\"message\":{\"required\":{\"value\":true,\"message\":\"This field is required\",\"global\":false,\"global_message\":\"This field is required\"}},\"cf-turnstile-response\":[]},\"debounce_time\":300,\"file_upload_settings\":[]};\n                            <\/script>\n            \n                <\/div>\n            <\/div>\n        <\/div>\n    <\/section>\n\n<\/div>\n\n<script>\n(function(){\n  const root = document.getElementById('energycle-industrial-chiller-page');\n  if(!root) return;\n  root.querySelectorAll('.energycle-faq-accordion-header').forEach(function(button){\n    button.addEventListener('click', function(){\n      const item = button.closest('.energycle-faq-accordion-item');\n      const open = button.getAttribute('aria-expanded') !== 'true';\n      root.querySelectorAll('.energycle-faq-accordion-header').forEach(function(other){\n        other.setAttribute('aria-expanded', 'false');\n        const otherItem = other.closest('.energycle-faq-accordion-item');\n        if (otherItem) otherItem.classList.remove('active');\n        const targetId = other.getAttribute('aria-controls');\n        const target = targetId ? document.getElementById(targetId) : null;\n        if (target) target.hidden = true;\n      });\n      if(open){\n        item.classList.add('active');\n        button.setAttribute('aria-expanded', 'true');\n        const targetId = button.getAttribute('aria-controls');\n        const target = targetId ? document.getElementById(targetId) : null;\n        if (target) target.hidden = false;\n      }\n    });\n  });\n})();\n<\/script>\n\n<script type=\"application\/ld+json\">\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@graph\": [\n    {\n      \"@type\": \"FAQPage\",\n      \"@id\": \"https:\/\/www.energycle.com\/industrial-air-cooled-chillers\/#faq\",\n      \"mainEntity\": [\n        {\n          \"@type\": \"Question\",\n          \"name\": \"Why are industrial chillers needed in plastic recycling and pelletizing?\",\n          \"acceptedAnswer\": {\n            \"@type\": \"Answer\",\n            \"text\": \"Plastic recycling lines involve intense heat generation across multiple stages. In pelletizing systems, molten polymer exiting the die head must be rapidly solidified in water ring pelletizers or cooling baths to achieve consistent pellet geometry and prevent clumping. Extruder feed throat cooling prevents premature polymer melting and bridging in the hopper, while PVC pulverizers require continuous chamber cooling to prevent thermal degradation.\"\n          }\n        },\n        {\n          \"@type\": \"Question\",\n          \"name\": \"What is the advantage of an air-cooled chiller over a water-cooled chiller?\",\n          \"acceptedAnswer\": {\n            \"@type\": \"Answer\",\n            \"text\": \"Air-cooled chillers reject heat directly to ambient air using built-in high-volume axial fans. They eliminate the need for external cooling towers, water treatment chemicals, tower circulation pumps, and makeup water supplies. This dramatically reduces installation footprint, avoids mineral scaling in hard water areas, and makes them ideal for recycling plants with restricted water availability or cold winter climates where outdoor cooling towers are prone to freezing.\"\n          }\n        },\n        {\n          \"@type\": \"Question\",\n          \"name\": \"How do I size the required chiller capacity for my extrusion or recycling line?\",\n          \"acceptedAnswer\": {\n            \"@type\": \"Answer\",\n            \"text\": \"Chiller sizing depends on the total thermal heat load of your line: Q = m * Cp * deltaT, where m is the polymer output throughput per hour (kg\/h), Cp is the specific heat capacity of the plastic, and deltaT is the temperature reduction from melt to solid state, plus additional cooling requirements for extruder feed throats and hydraulic power units. Energycle engineers can calculate your exact load based on your line setup.\"\n          }\n        },\n        {\n          \"@type\": \"Question\",\n          \"name\": \"Can the chiller operate with glycol for sub-zero cooling?\",\n          \"acceptedAnswer\": {\n            \"@type\": \"Answer\",\n            \"text\": \"Yes. When cooling setpoints below 5\u00b0C are required\u2014or in cold geographical regions where outdoor ambient temperatures drop below freezing\u2014the system can be charged with an ethylene or propylene glycol water solution (typically 20%\u201335% concentration). This prevents evaporator freezing and allows stable operation down to -5\u00b0C to -10\u00b0C fluid delivery.\"\n          }\n        },\n        {\n          \"@type\": \"Question\",\n          \"name\": \"What safety interlocks protect the chiller during 24\/7 continuous operation?\",\n          \"acceptedAnswer\": {\n            \"@type\": \"Answer\",\n            \"text\": \"Energycle packaged chillers include an 8-point automated protection matrix: compressor internal thermal overload protection, high and low refrigerant pressure cutout switches, reverse-phase and phase-loss electrical monitoring, anti-freeze thermostat safety, water flow switch cutoff, water level sensors in the reservoir, and an emergency stop circuit.\"\n          }\n        }\n      ]\n    }\n  ]\n}\n<\/script>\n","protected":false},"excerpt":{"rendered":"<p>Industrijski zrakom hla\u0111eni rashladni ure\u0111aji dizajnirani su za u\u010dinkovito hla\u0111enje teku\u0107ina i odvla\u017eivanje zraka u industrijskim i komercijalnim primjenama. S zna\u010dajkama poput visokou\u010dinkovitih kompresora, sigurnosne za\u0161tite, energetske u\u010dinkovitosti i naprednih sustava upravljanja, ovi rashladni ure\u0111aji osiguravaju optimalan rad i sprje\u010davaju pregrijavanje opreme.<\/p>","protected":false},"author":1,"featured_media":21414,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-12237","page","type-page","status-publish","has-post-thumbnail","hentry"],"_links":{"self":[{"href":"https:\/\/www.energycle.com\/hr\/wp-json\/wp\/v2\/pages\/12237","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.energycle.com\/hr\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.energycle.com\/hr\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.energycle.com\/hr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.energycle.com\/hr\/wp-json\/wp\/v2\/comments?post=12237"}],"version-history":[{"count":6,"href":"https:\/\/www.energycle.com\/hr\/wp-json\/wp\/v2\/pages\/12237\/revisions"}],"predecessor-version":[{"id":21415,"href":"https:\/\/www.energycle.com\/hr\/wp-json\/wp\/v2\/pages\/12237\/revisions\/21415"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.energycle.com\/hr\/wp-json\/wp\/v2\/media\/21414"}],"wp:attachment":[{"href":"https:\/\/www.energycle.com\/hr\/wp-json\/wp\/v2\/media?parent=12237"}],"curies":[{"name":"radni list","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}