{"id":11455,"date":"2025-06-11T10:30:04","date_gmt":"2025-06-11T08:30:04","guid":{"rendered":"https:\/\/www.energycle.com\/?page_id=11455"},"modified":"2026-03-28T03:02:08","modified_gmt":"2026-03-28T02:02:08","slug":"sistema-di-flottazione-ad-aria-disciolta-daf","status":"publish","type":"page","link":"https:\/\/www.energycle.com\/it\/sistema-di-flottazione-ad-aria-disciolta-daf\/","title":{"rendered":"Sistema di flottazione ad aria disciolta (DAF)"},"content":{"rendered":"<div class=\"wpb-content-wrapper\">\r\n<div data-vc-full-width=\"true\" data-vc-full-width-init=\"false\" data-vc-stretch-content=\"true\" class=\"vc_row ts-row wpb_row vc_row-fluid vc_custom_1774147520799 ts-total-col-1 ts-zindex-0 ts-bgimage-position-center_center\">\r\n\r\n        \r\n\t\r\n\t\r\n\t\t\r\n<div class=\"ts-column wpb_column vc_column_container vc_col-sm-12 ts-zindex-0\">\r\n\t<div class=\"vc_column-inner  \">\r\n\t\t\t\t<div class=\"wpb_wrapper\">\r\n\t\t\t\n\t<div class=\"wpb_raw_code wpb_raw_html wpb_content_element\" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<div id=\"erm-daf-sys\" class=\"energycle-hero-page\" aria-label=\"Dissolved Air Flotation DAF system for industrial wastewater treatment\">\n\n    <section id=\"overview\" class=\"energycle-hero-section\">\n        <div class=\"energycle-hero-inner\">\n            <div class=\"energycle-hero-content\">\n                <p class=\"energycle-hero-eyebrow\">Industrial Wastewater Treatment Equipment<\/p>\n                <h1 class=\"energycle-hero-title\">Dissolved Air Flotation (DAF) System for Industrial Wastewater Treatment<\/h1>\n                <p class=\"energycle-hero-subtitle\">A dissolved air flotation system that separates suspended solids, emulsified oils, grease, and biological flocs from industrial wastewater using micro-bubble flotation. DAF is used in plastic recycling, food processing, oil and gas, meat and poultry, paper and pulp, chemical, and municipal sectors where settling tanks alone cannot deliver consistent effluent quality or regulatory compliance.<\/p>\n                <div>\n                    <a href=\"#inquiry-form\" class=\"energycle-hero-cta\">Get a Custom Quote<\/a>\n                    <a href=\"#specs\" class=\"energycle-hero-cta-outline\">View Specifications<\/a>\n                <\/div>\n                <nav class=\"energycle-hero-quicklinks\" aria-label=\"On-page navigation\">\n                    <a href=\"#benefits\" class=\"energycle-hero-quicklinks-item\">Benefits<\/a>\n                    <a href=\"#applications\" class=\"energycle-hero-quicklinks-item\">Applications<\/a>\n                    <a href=\"#process\" class=\"energycle-hero-quicklinks-item\">Process<\/a>\n                    <a href=\"#compare\" class=\"energycle-hero-quicklinks-item\">Compare<\/a>\n                    <a href=\"#specs\" class=\"energycle-hero-quicklinks-item\">Specs<\/a>\n                    <a href=\"#gallery\" class=\"energycle-hero-quicklinks-item\">Gallery<\/a>\n                    <a href=\"#related\" class=\"energycle-hero-quicklinks-item\">Related<\/a>\n                    <a href=\"#faq\" class=\"energycle-hero-quicklinks-item\">FAQ<\/a>\n                <\/nav>\n            <\/div>\n        <\/div>\n    <\/section>\n\n    <section id=\"benefits\">\n        <div class=\"energycle-wrapper\">\n            <div class=\"energycle-section-header\">\n                <h2 class=\"energycle-section-title\">Why Industrial Plants Choose DAF Over Conventional Clarifiers<\/h2>\n                <p class=\"energycle-section-desc\">Gravity settling works well for heavy, dense solids \u2014 but most industrial effluents carry light suspended solids, emulsified fats, oils, and biological flocs that will not settle reliably. DAF lifts these contaminants to the surface using micro-bubbles, giving operators consistent removal in a compact footprint.<\/p>\n            <\/div>\n            <div class=\"energycle-advantage-grid\">\n                <article class=\"energycle-advantage-card energycle-span-2\">\n                    <div class=\"energycle-advantage-header\">\n                        <div class=\"energycle-advantage-header-icon\"><i class=\"fa-solid fa-bullseye\" aria-hidden=\"true\"><\/i><\/div>\n                        <h3>High TSS and FOG Removal from Difficult Streams<\/h3>\n                    <\/div>\n                    <p>DAF is designed for wastewater where suspended solids and fats, oils, and grease are too light or too emulsified for settling tanks to capture reliably, delivering up to 95\u201399% removal when the system is correctly paired with coagulation and flocculation chemistry.<\/p>\n                <\/article>\n                <article class=\"energycle-advantage-card\">\n                    <div class=\"energycle-advantage-header\">\n                        <div class=\"energycle-advantage-header-icon\"><i class=\"fa-solid fa-minimize\" aria-hidden=\"true\"><\/i><\/div>\n                        <h3>Compact Footprint vs Conventional Clarifiers<\/h3>\n                    <\/div>\n                    <p>DAF units operate at much higher hydraulic loading rates than traditional gravity settlers, allowing the same throughput in a fraction of the plan area \u2014 important for plants with space constraints or retrofit needs.<\/p>\n                <\/article>\n                <article class=\"energycle-advantage-card\">\n                    <div class=\"energycle-advantage-header\">\n                        <div class=\"energycle-advantage-header-icon\"><i class=\"fa-solid fa-robot\" aria-hidden=\"true\"><\/i><\/div>\n                        <h3>PLC-Controlled and Suitable for Continuous Operation<\/h3>\n                    <\/div>\n                    <p>Automated dosing, skimmer speed control, and recycle pump management allow the system to handle variable influent loads with minimal operator intervention, supporting 24\/7 continuous production schedules.<\/p>\n                <\/article>\n                <article class=\"energycle-advantage-card energycle-span-2\">\n                    <div class=\"energycle-advantage-header\">\n                        <div class=\"energycle-advantage-header-icon\"><i class=\"fa-solid fa-shield-halved\" aria-hidden=\"true\"><\/i><\/div>\n                        <h3>Corrosion-Resistant Build for Harsh Process Environments<\/h3>\n                    <\/div>\n                    <p>SS304 or SS316L stainless steel tank and component options are available for applications involving caustic, acidic, or saline wastewater streams, where carbon steel would require frequent replacement.<\/p>\n                <\/article>\n                <article class=\"energycle-advantage-card energycle-span-2\">\n                    <div class=\"energycle-advantage-header\">\n                        <div class=\"energycle-advantage-header-icon\"><i class=\"fa-solid fa-scale-balanced\" aria-hidden=\"true\"><\/i><\/div>\n                        <h3>Reduces Load on Downstream Biological Treatment<\/h3>\n                    <\/div>\n                    <p>By removing suspended solids and much of the oil and grease upstream, DAF reduces BOD and TSS load on aerobic or anaerobic biological stages, improving their stability and reducing aeration energy costs.<\/p>\n                <\/article>\n                <article class=\"energycle-advantage-card\">\n                    <div class=\"energycle-advantage-header\">\n                        <div class=\"energycle-advantage-header-icon\"><i class=\"fa-solid fa-layer-group\" aria-hidden=\"true\"><\/i><\/div>\n                        <h3>Drier Sludge Reduces Disposal Cost<\/h3>\n                    <\/div>\n                    <p>Floated sludge from DAF typically has higher solids content than sludge from settling, which means lower volume for dewatering and reduced hauling and disposal cost when paired with a press or centrifuge.<\/p>\n                <\/article>\n            <\/div>\n        <\/div>\n    <\/section>\n\n    <section id=\"recycling-benefits\">\n        <div class=\"energycle-wrapper\">\n            <div class=\"energycle-section-header\">\n                <h2 class=\"energycle-section-title\">Essential for Plastic Recycling Wash Water Loops<\/h2>\n                <p class=\"energycle-section-desc\">With the integration of our dedicated recycling water treatment solutions, this DAF system is highly optimized for post-consumer plastic washing lines dealing with variable contamination.<\/p>\n            <\/div>\n            <div class=\"energycle-advantage-grid\">\n                <article class=\"energycle-advantage-card energycle-span-2\">\n                    <div class=\"energycle-advantage-header\">\n                        <div class=\"energycle-advantage-header-icon\"><i class=\"fa-solid fa-water\" aria-hidden=\"true\"><\/i><\/div>\n                        <h3>Closed-Loop Water Recycling Stability<\/h3>\n                    <\/div>\n                    <p>By removing suspended solids and floatable contamination more consistently, DAF helps keep wash water usable for recirculation and reduces the risk of dirt redepositing on cleaned plastic flakes.<\/p>\n                <\/article>\n                <article class=\"energycle-advantage-card\">\n                    <div class=\"energycle-advantage-header\">\n                        <div class=\"energycle-advantage-header-icon\"><i class=\"fa-solid fa-recycle\" aria-hidden=\"true\"><\/i><\/div>\n                        <h3>Supports High-Ratio Water Reuse<\/h3>\n                    <\/div>\n                    <p>Cleaner process water means less fresh water demand, fewer water-quality swings, and a more stable washing line overall.<\/p>\n                <\/article>\n                <article class=\"energycle-advantage-card energycle-span-2\">\n                    <div class=\"energycle-advantage-header\">\n                        <div class=\"energycle-advantage-header-icon\"><i class=\"fa-solid fa-oil-can\" aria-hidden=\"true\"><\/i><\/div>\n                        <h3>Adapts to Post-Consumer Materials<\/h3>\n                    <\/div>\n                    <p>When incoming contamination swings day to day with post-consumer feedstocks, DAF helps smooth out the impact on wash water quality better than purely passive settling systems.<\/p>\n                <\/article>\n                <article class=\"energycle-advantage-card\">\n                    <div class=\"energycle-advantage-header\">\n                        <div class=\"energycle-advantage-header-icon\"><i class=\"fa-solid fa-industry\" aria-hidden=\"true\"><\/i><\/div>\n                        <h3>Fits as a Core Auxiliary Module<\/h3>\n                    <\/div>\n                    <p>In many recycling plants, DAF is best treated as part of the washing line design rather than an afterthought added once water problems appear.<\/p>\n                <\/article>\n            <\/div>\n        <\/div>\n    <\/section>\n\n    <section id=\"applications\">\n        <div class=\"energycle-wrapper\">\n            <div class=\"energycle-section-header\">\n                <h2 class=\"energycle-section-title\">Industry Applications<\/h2>\n                <p class=\"energycle-section-desc\">DAF systems are applied wherever industrial processes generate wastewater with suspended solids, oils, greases, or floatable biological material that must be clarified before discharge or reuse.<\/p>\n            <\/div>\n            <div class=\"energycle-app-bento\">\n                <article class=\"energycle-app-bento-card\">\n                    <div class=\"energycle-app-bento-icon\"><i class=\"fa-solid fa-recycle\" aria-hidden=\"true\"><\/i><\/div>\n                    <h3 class=\"energycle-app-bento-title\">Plastic Recycling Washing Lines<\/h3>\n                    <p class=\"energycle-app-bento-desc\">Used after screening and equalization to remove fines, labels, oils, detergent carryover, and microplastics from recycling wash water to support closed loops.<\/p>\n                <\/article>\n                <article class=\"energycle-app-bento-card\">\n                    <div class=\"energycle-app-bento-icon\"><i class=\"fa-solid fa-utensils\" aria-hidden=\"true\"><\/i><\/div>\n                    <h3 class=\"energycle-app-bento-title\">Food and Beverage Processing<\/h3>\n                    <p class=\"energycle-app-bento-desc\">Removes fats, oils, grease, starch, proteins, and suspended organics from process water before biological treatment or discharge to comply with trade effluent consent.<\/p>\n                <\/article>\n                <article class=\"energycle-app-bento-card\">\n                    <div class=\"energycle-app-bento-icon\"><i class=\"fa-solid fa-drumstick-bite\" aria-hidden=\"true\"><\/i><\/div>\n                    <h3 class=\"energycle-app-bento-title\">Meat, Poultry, and Seafood Processing<\/h3>\n                    <p class=\"energycle-app-bento-desc\">Handles high-strength effluent with elevated BOD, blood, animal fats, and protein solids that would overload biological treatment if not removed first.<\/p>\n                <\/article>\n                <article class=\"energycle-app-bento-card\">\n                    <div class=\"energycle-app-bento-icon\"><i class=\"fa-solid fa-oil-well\" aria-hidden=\"true\"><\/i><\/div>\n                    <h3 class=\"energycle-app-bento-title\">Oil and Gas, Refinery Effluent<\/h3>\n                    <p class=\"energycle-app-bento-desc\">Separates emulsified hydrocarbons and suspended solids from produced water, wash water, and refinery effluent streams where oil-water separation is required before further treatment or discharge.<\/p>\n                <\/article>\n                <article class=\"energycle-app-bento-card\">\n                    <div class=\"energycle-app-bento-icon\"><i class=\"fa-solid fa-scroll\" aria-hidden=\"true\"><\/i><\/div>\n                    <h3 class=\"energycle-app-bento-title\">Pulp, Paper, and Board Mills<\/h3>\n                    <p class=\"energycle-app-bento-desc\">Recovers fine fibers, fillers, and coating pigments from white water and screen room effluent, supporting both fiber recovery and clarification before discharge or reuse.<\/p>\n                <\/article>\n                <article class=\"energycle-app-bento-card\">\n                    <div class=\"energycle-app-bento-icon\"><i class=\"fa-solid fa-flask\" aria-hidden=\"true\"><\/i><\/div>\n                    <h3 class=\"energycle-app-bento-title\">Chemical and Specialty Manufacturing<\/h3>\n                    <p class=\"energycle-app-bento-desc\">Applied for removal of emulsified solvents, pigments, surfactants, and suspended particles from process effluents where chemical pretreatment assists micro-bubble attachment.<\/p>\n                <\/article>\n            <\/div>\n        <\/div>\n    <\/section>\n\n    <section id=\"process\" class=\"energycle-process-section\">\n        <div class=\"energycle-wrapper\">\n            <div class=\"energycle-section-header\">\n                <h2 class=\"energycle-section-title\">How a Dissolved Air Flotation System Works<\/h2>\n                <p class=\"energycle-section-desc\">DAF uses pressurized air dissolved into water under pressure, which is then released to form micro-bubbles that attach to suspended particles and carry them to the surface as a skimmable float layer.<\/p>\n            <\/div>\n            <div class=\"energycle-process-flow-h\">\n                <article class=\"energycle-process-h-step\">\n                    <div class=\"energycle-process-h-step-num\">1<\/div>\n                    <span class=\"energycle-process-h-step-icon\"><i class=\"fa-solid fa-arrows-rotate\" aria-hidden=\"true\"><\/i><\/span>\n                    <h3 class=\"energycle-process-h-step-title\">Pretreatment and Chemical Dosing<\/h3>\n                    <p class=\"energycle-process-h-step-desc\">Wastewater passes through screening and equalization, then receives coagulant and flocculant to destabilize colloids and form larger flocs that micro-bubbles can carry to the surface.<\/p>\n                    <div class=\"energycle-process-h-step-tags\">\n                        <span class=\"tag\">Coagulation<\/span>\n                        <span class=\"tag\">Flocculation<\/span>\n                    <\/div>\n                <\/article>\n                <article class=\"energycle-process-h-step\">\n                    <div class=\"energycle-process-h-step-num\">2<\/div>\n                    <span class=\"energycle-process-h-step-icon\"><i class=\"fa-solid fa-compress\" aria-hidden=\"true\"><\/i><\/span>\n                    <h3 class=\"energycle-process-h-step-title\">Pressurized Air Dissolution<\/h3>\n                    <p class=\"energycle-process-h-step-desc\">A recycle stream of clarified water is pressurized to 400\u2013600 kPa and saturated with compressed air in a pressurization vessel, dissolving air into solution.<\/p>\n                    <div class=\"energycle-process-h-step-tags\">\n                        <span class=\"tag\">Recycle Stream<\/span>\n                        <span class=\"tag\">Pressurization<\/span>\n                    <\/div>\n                <\/article>\n                <article class=\"energycle-process-h-step\">\n                    <div class=\"energycle-process-h-step-num\">3<\/div>\n                    <span class=\"energycle-process-h-step-icon\"><i class=\"fa-solid fa-burst\" aria-hidden=\"true\"><\/i><\/span>\n                    <h3 class=\"energycle-process-h-step-title\">Micro-Bubble Release and Flotation<\/h3>\n                    <p class=\"energycle-process-h-step-desc\">The saturated recycle is released into the flotation tank through nozzles. The pressure drop causes millions of micro-bubbles (20\u201370 \u00b5m) to form and attach to flocs and particles, lifting them to the surface.<\/p>\n                    <div class=\"energycle-process-h-step-tags\">\n                        <span class=\"tag\">20\u201370 \u00b5m Bubbles<\/span>\n                        <span class=\"tag\">Flotation Cell<\/span>\n                    <\/div>\n                <\/article>\n                <article class=\"energycle-process-h-step\">\n                    <div class=\"energycle-process-h-step-num\">4<\/div>\n                    <span class=\"energycle-process-h-step-icon\"><i class=\"fa-solid fa-broom\" aria-hidden=\"true\"><\/i><\/span>\n                    <h3 class=\"energycle-process-h-step-title\">Surface Skimming and Sludge Removal<\/h3>\n                    <p class=\"energycle-process-h-step-desc\">A mechanical skimmer continuously removes the floated sludge blanket and discharges it for dewatering. Clarified water exits from the bottom of the flotation tank.<\/p>\n                    <div class=\"energycle-process-h-step-tags\">\n                        <span class=\"tag\">Skimmer<\/span>\n                        <span class=\"tag\">Sludge Discharge<\/span>\n                    <\/div>\n                <\/article>\n                <article class=\"energycle-process-h-step\">\n                    <div class=\"energycle-process-h-step-num\">5<\/div>\n                    <span class=\"energycle-process-h-step-icon\"><i class=\"fa-solid fa-glass-water\" aria-hidden=\"true\"><\/i><\/span>\n                    <h3 class=\"energycle-process-h-step-title\">Clarified Effluent to Discharge or Reuse<\/h3>\n                    <p class=\"energycle-process-h-step-desc\">Treated effluent exits the tank ready for discharge to drain, biological treatment, or internal recirculation depending on the required effluent quality standard.<\/p>\n                    <div class=\"energycle-process-h-step-tags\">\n                        <span class=\"tag\">Effluent Discharge<\/span>\n                        <span class=\"tag\">Water Reuse<\/span>\n                    <\/div>\n                <\/article>\n            <\/div>\n        <\/div>\n    <\/section>\n\n    <section id=\"compare\">\n        <div class=\"energycle-wrapper\">\n            <div class=\"energycle-section-header\">\n                <h2 class=\"energycle-section-title\">DAF vs Gravity Settling vs Lamella Clarifiers<\/h2>\n                <p class=\"energycle-section-desc\">Each clarification technology handles a different contamination profile. DAF is not always the right choice \u2014 but for light, floatable, or emulsified contamination it consistently outperforms gravity-based methods.<\/p>\n            <\/div>\n            <div class=\"energycle-compare-table-wrap\">\n                <table class=\"energycle-compare-table\">\n                    <thead>\n                        <tr>\n                            <th>Decision Factor<\/th>\n                            <th class=\"ours\">DAF System<\/th>\n                            <th>Gravity Settling Tank<\/th>\n                            <th>Lamella Clarifier<\/th>\n                        <\/tr>\n                    <\/thead>\n                    <tbody>\n                        <tr>\n                            <td>Best at Removing<\/td>\n                            <td><span class=\"energycle-compare-check\"><\/span> Light suspended solids, emulsified oils, grease, biological flocs<\/td>\n                            <td>Dense, fast-settling solids such as sand, grit, heavy sludge<\/td>\n                            <td>Medium-density suspended solids in high-flow, low-footprint applications<\/td>\n                        <\/tr>\n                        <tr>\n                            <td>Performance on FOG<\/td>\n                            <td><span class=\"energycle-compare-check\"><\/span> Strong \u2014 micro-bubbles lift emulsified oil to surface<\/td>\n                            <td><span class=\"energycle-compare-cross\"><\/span> Weak \u2014 emulsified FOG does not settle by gravity<\/td>\n                            <td><span class=\"energycle-compare-cross\"><\/span> Limited \u2014 lamella plates do not address emulsified oil<\/td>\n                        <\/tr>\n                        <tr>\n                            <td>Footprint<\/td>\n                            <td><span class=\"energycle-compare-check\"><\/span> Compact \u2014 high hydraulic loading rate<\/td>\n                            <td><span class=\"energycle-compare-cross\"><\/span> Large \u2014 requires long residence time<\/td>\n                            <td><span class=\"energycle-compare-check\"><\/span> Compact \u2014 inclined plates increase effective area<\/td>\n                        <\/tr>\n                        <tr>\n                            <td>Sludge Characteristics<\/td>\n                            <td><span class=\"energycle-compare-check\"><\/span> Drier float sludge \u2014 easier to dewater<\/td>\n                            <td>Wet settled sludge \u2014 higher water content, higher disposal volume<\/td>\n                            <td>Similar to conventional settling \u2014 depends on influent and chemistry<\/td>\n                        <\/tr>\n                        <tr>\n                            <td>When to Choose<\/td>\n                            <td><span class=\"energycle-compare-check\"><\/span> When TSS or FOG removal is the primary target and space is limited<\/td>\n                            <td>When the main goal is coarse solids removal as a pretreatment stage<\/td>\n                            <td>When high flow rate and medium solids removal are needed in a compact unit<\/td>\n                        <\/tr>\n                    <\/tbody>\n                <\/table>\n            <\/div>\n        <\/div>\n    <\/section>\n\n    <section id=\"specs\">\n        <div class=\"energycle-wrapper\">\n            <div class=\"energycle-section-header\">\n                <h2 class=\"energycle-section-title\">Technical Specifications<\/h2>\n                <p class=\"energycle-section-desc\">Standard DAF models cover common industrial flow ranges. Higher-capacity and custom configurations are available to match specific wastewater loads, influent characteristics, and effluent targets.<\/p>\n            <\/div>\n            <div class=\"energycle-specs-table-wrap\">\n                <table class=\"energycle-specs-table\" aria-label=\"Technical specifications for DAF industrial wastewater treatment system\">\n                    <thead>\n                        <tr>\n                            <th>Model<\/th>\n                            <th>ERM-DAF10<\/th>\n                            <th>ERM-DAF20<\/th>\n                            <th>ERM-DAF50<\/th>\n                            <th>ERM-DAF100<\/th>\n                        <\/tr>\n                    <\/thead>\n                    <tbody>\n                        <tr>\n                            <td>Flow Capacity<\/td>\n                            <td>10 m\u00b3\/h<\/td>\n                            <td>20 m\u00b3\/h<\/td>\n                            <td>50 m\u00b3\/h<\/td>\n                            <td>100 m\u00b3\/h<\/td>\n                        <\/tr>\n                        <tr>\n                            <td>Motor Power<\/td>\n                            <td>4.0 kW<\/td>\n                            <td>5.5 kW<\/td>\n                            <td>11 kW<\/td>\n                            <td>18.5 kW<\/td>\n                        <\/tr>\n                        <tr>\n                            <td>Saturation Pressure<\/td>\n                            <td>400\u2013600 kPa<\/td>\n                            <td>400\u2013600 kPa<\/td>\n                            <td>400\u2013600 kPa<\/td>\n                            <td>400\u2013600 kPa<\/td>\n                        <\/tr>\n                        <tr>\n                            <td>Dissolved Air Ratio<\/td>\n                            <td>5\u201315%<\/td>\n                            <td>5\u201315%<\/td>\n                            <td>5\u201315%<\/td>\n                            <td>5\u201315%<\/td>\n                        <\/tr>\n                    <\/tbody>\n                <\/table>\n            <\/div>\n            <div class=\"energycle-section-header\">\n                <p class=\"energycle-section-desc\">SS304 or SS316L tank material, PLC control panel, automatic chemical dosing integration, and CE certification are available as configuration options depending on application requirements.<\/p>\n            <\/div>\n        <\/div>\n    <\/section>\n\n    <section id=\"gallery\" class=\"energycle-gallery-section\">\n        <div class=\"energycle-wrapper\">\n            <div class=\"energycle-section-header\">\n                <h2 class=\"energycle-section-title\">Machine Gallery<\/h2>\n                <p class=\"energycle-section-desc\">Reference views of Energycle DAF systems in industrial wastewater treatment installations.<\/p>\n            <\/div>\n            <div class=\"energycle-gallery-grid\">\n                <div class=\"energycle-gallery-item\">\n                    <img src=\"https:\/\/recycling.imgix.net\/image\/DAF\/Dissolved%20Air%20Flotation%20(DAF)-2.webp\"\n                        alt=\"Complete dissolved air flotation DAF system unit in industrial installation\" loading=\"lazy\"\n                        decoding=\"async\" width=\"1024\" height=\"576\">\n                <\/div>\n            <\/div>\n        <\/div>\n    <\/section>\n\n    <section id=\"related\">\n        <div class=\"energycle-wrapper\">\n            <div class=\"energycle-section-header\">\n                <h2 class=\"energycle-section-title\">Related Equipment<\/h2>\n                <p class=\"energycle-section-desc\">These are the most common upstream and downstream stages when integrating a DAF system into an industrial wastewater treatment train.<\/p>\n            <\/div>\n            <div class=\"energycle-product-grid\">\n                <a href=\"https:\/\/www.energycle.com\/recycling-solutions\/pp-woven-bags-raffia-recycling-line\/\"\n                    class=\"energycle-product-card energycle-product-col-span-1\" target=\"_blank\"\n                    rel=\"noopener noreferrer\">\n                    <h3>PP Woven Bags &amp; Raffia Recycling Line<\/h3>\n                    <p>Compare this water-intensive washing line when you are designing a full recycling system where DAF may become an essential part of the wastewater loop.<\/p>\n                <\/a>\n                <a href=\"https:\/\/www.energycle.com\/screw-press-dewatering-system\/\"\n                    class=\"energycle-product-card energycle-product-col-span-1\" target=\"_blank\"\n                    rel=\"noopener noreferrer\">\n                    <h3>Screw Press Dewatering System<\/h3>\n                    <p>Use downstream of DAF to reduce floated sludge volume mechanically before disposal, cutting hauling cost and landfill load.<\/p>\n                <\/a>\n                <a href=\"https:\/\/www.energycle.com\/recycling-solutions\/\"\n                    class=\"energycle-product-card energycle-product-col-span-1\" target=\"_blank\"\n                    rel=\"noopener noreferrer\">\n                    <h3>Plastic Recycling Line Solutions<\/h3>\n                    <p>See complete washing and recycling line configurations where DAF is commonly specified as part of the water management system.<\/p>\n                <\/a>\n            <\/div>\n        <\/div>\n    <\/section>\n\n    <section id=\"faq\" class=\"energycle-faq-section\">\n        <div class=\"energycle-wrapper energycle-faq-container\">\n            <div class=\"energycle-section-header\">\n                <h2 class=\"energycle-section-title\">Frequently Asked Questions<\/h2>\n                <p class=\"energycle-section-desc\">Common questions from plant engineers and facility managers evaluating DAF systems for industrial wastewater treatment.<\/p>\n            <\/div>\n            <div>\n                <div class=\"energycle-faq-accordion-item\">\n                    <button type=\"button\" class=\"energycle-faq-accordion-header\" aria-expanded=\"false\" id=\"daf-sys-faq-t-1\"\n                        aria-controls=\"daf-sys-faq-c-1\">\n                        <h3>What removal rates can a DAF system achieve for TSS and FOG?<\/h3>\n                        <i class=\"fa-solid fa-plus energycle-faq-accordion-icon\" aria-hidden=\"true\"><\/i>\n                    <\/button>\n                    <div class=\"energycle-faq-accordion-content\" id=\"daf-sys-faq-c-1\" role=\"region\"\n                        aria-labelledby=\"daf-sys-faq-t-1\">\n                        <p>When correctly paired with coagulation and flocculation chemistry suited to the specific wastewater, DAF systems typically achieve 95\u201399% TSS removal and similar FOG removal efficiency. Exact performance depends on influent characteristics, chemical dose, and recycle ratio, and should be confirmed through a jar test or pilot trial.<\/p>\n                    <\/div>\n                <\/div>\n                <div class=\"energycle-faq-accordion-item\">\n                    <button type=\"button\" class=\"energycle-faq-accordion-header\" aria-expanded=\"false\" id=\"daf-sys-faq-t-2\"\n                        aria-controls=\"daf-sys-faq-c-2\">\n                        <h3>Does DAF always require chemical pretreatment?<\/h3>\n                        <i class=\"fa-solid fa-plus energycle-faq-accordion-icon\" aria-hidden=\"true\"><\/i>\n                    <\/button>\n                    <div class=\"energycle-faq-accordion-content\" id=\"daf-sys-faq-c-2\" role=\"region\"\n                        aria-labelledby=\"daf-sys-faq-t-2\">\n                        <p>For most industrial applications, coagulant and flocculant dosing significantly improves performance, especially on emulsified oils and fine suspended solids. Some clean single-phase feeds can be treated without chemistry, but wastewater with complex contamination nearly always benefits from chemical conditioning upstream of the flotation cell.<\/p>\n                    <\/div>\n                <\/div>\n                <div class=\"energycle-faq-accordion-item\">\n                    <button type=\"button\" class=\"energycle-faq-accordion-header\" aria-expanded=\"false\" id=\"daf-sys-faq-t-3\"\n                        aria-controls=\"daf-sys-faq-c-3\">\n                        <h3>How long does installation and commissioning take?<\/h3>\n                        <i class=\"fa-solid fa-plus energycle-faq-accordion-icon\" aria-hidden=\"true\"><\/i>\n                    <\/button>\n                    <div class=\"energycle-faq-accordion-content\" id=\"daf-sys-faq-c-3\" role=\"region\"\n                        aria-labelledby=\"daf-sys-faq-t-3\">\n                        <p>Timeline varies with project complexity. Standard packaged units can be delivered and commissioned within a few weeks. Larger or custom-engineered systems designed around specific influent conditions, flow rates, and integration requirements will have longer lead times confirmed during the engineering phase.<\/p>\n                    <\/div>\n                <\/div>\n                <div class=\"energycle-faq-accordion-item\">\n                    <button type=\"button\" class=\"energycle-faq-accordion-header\" aria-expanded=\"false\" id=\"daf-sys-faq-t-4\"\n                        aria-controls=\"daf-sys-faq-c-4\">\n                        <h3>Can DAF handle variable flow rates and influent concentrations?<\/h3>\n                        <i class=\"fa-solid fa-plus energycle-faq-accordion-icon\" aria-hidden=\"true\"><\/i>\n                    <\/button>\n                    <div class=\"energycle-faq-accordion-content\" id=\"daf-sys-faq-c-4\" role=\"region\"\n                        aria-labelledby=\"daf-sys-faq-t-4\">\n                        <p>Yes. PLC-controlled recycle ratio, chemical dosing, and skimmer speed allow the system to adapt to fluctuating loads. An equalization tank upstream further stabilizes the influent, which is the most effective way to protect DAF performance during production peaks or batch discharge events.<\/p>\n                    <\/div>\n                <\/div>\n                <div class=\"energycle-faq-accordion-item\">\n                    <button type=\"button\" class=\"energycle-faq-accordion-header\" aria-expanded=\"false\" id=\"daf-sys-faq-t-5\"\n                        aria-controls=\"daf-sys-faq-c-5\">\n                        <h3>What information is needed to size a DAF system?<\/h3>\n                        <i class=\"fa-solid fa-plus energycle-faq-accordion-icon\" aria-hidden=\"true\"><\/i>\n                    <\/button>\n                    <div class=\"energycle-faq-accordion-content\" id=\"daf-sys-faq-c-5\" role=\"region\"\n                        aria-labelledby=\"daf-sys-faq-t-5\">\n                        <p>Please provide peak and average wastewater flow rate, influent TSS, FOG, and BOD concentrations, pH and temperature range, effluent discharge standard or reuse target, available footprint, and whether an equalization or chemical dosing system is already in place. A jar test with your wastewater sample allows the team to confirm chemical type, dose, and expected removal efficiency before system design.<\/p>\n                    <\/div>\n                <\/div>\n                <div class=\"energycle-faq-accordion-item\">\n                    <button type=\"button\" class=\"energycle-faq-accordion-header\" aria-expanded=\"false\" id=\"daf-sys-faq-t-6\"\n                        aria-controls=\"daf-sys-faq-c-6\">\n                        <h3>Can treated water be reused in closed-loop washing lines?<\/h3>\n                        <i class=\"fa-solid fa-plus energycle-faq-accordion-icon\" aria-hidden=\"true\"><\/i>\n                    <\/button>\n                    <div class=\"energycle-faq-accordion-content\" id=\"daf-sys-faq-c-6\" role=\"region\"\n                        aria-labelledby=\"daf-sys-faq-t-6\">\n                        <p>In many applications, such as plastic recycling and industrial washing, yes. DAF dramatically improves water stability by removing suspended solids and floatables, allowing for a high ratio of process water recirculation.<\/p>\n                    <\/div>\n                <\/div>\n            <\/div>\n        <\/div>\n    <\/section>\n\n    <section id=\"inquiry-form\" class=\"energycle-cta-section\">\n        <div class=\"energycle-wrapper energycle-cta-inner\">\n            <div class=\"energycle-cta-content\">\n                <h2 class=\"energycle-cta-title\">Need a DAF System Sized for Your Industrial Wastewater?<\/h2>\n                <p class=\"energycle-cta-subtitle\">Share your flow rate, influent characteristics, effluent standard, and available footprint. Our engineers will recommend the right DAF configuration, recycle ratio, and chemical pretreatment approach for your application.<\/p>\n            <\/div>\n            <div class=\"energycle-cta-form\">\n                <div class='fluentform ff-default fluentform_wrapper_1 ffs_default_wrap'><form data-form_id=\"1\" id=\"fluentform_1\" class=\"frm-fluent-form fluent_form_1 ff-el-form-top ff_form_instance_1_1 ff-form-loading ffs_default\" data-form_instance=\"ff_form_instance_1_1\" method=\"POST\" ><fieldset  style=\"border: none!important;margin: 0!important;padding: 0!important;background-color: transparent!important;box-shadow: none!important;outline: none!important; min-inline-size: 100%;\">\n                    <legend class=\"ff_screen_reader_title\" style=\"display: block; margin: 0!important;padding: 0!important;height: 0!important;text-indent: -999999px;width: 0!important;overflow:hidden;\">Contact Form<\/legend><input type='hidden' name='__fluent_form_embded_post_id' value='11455' \/><input type=\"hidden\" id=\"_fluentform_1_fluentformnonce\" name=\"_fluentform_1_fluentformnonce\" value=\"4b81bb7330\" \/><input type=\"hidden\" name=\"_wp_http_referer\" value=\"\/it\/wp-json\/wp\/v2\/pages\/11455\" \/><div data-type=\"name-element\" data-name=\"names\" class=\" ff-field_container ff-name-field-wrapper\" ><div class='ff-t-container'><div class='ff-t-cell '><div class='ff-el-group'><div class=\"ff-el-input--label asterisk-right\"><label for='ff_1_names_first_name_' id='label_ff_1_names_first_name_' >First Name<\/label><\/div><div class='ff-el-input--content'><input type=\"text\" name=\"names[first_name]\" id=\"ff_1_names_first_name_\" class=\"ff-el-form-control\" placeholder=\"First Name\" aria-invalid=\"false\" aria-required=false><\/div><\/div><\/div><div class='ff-t-cell '><div class='ff-el-group'><div class=\"ff-el-input--label asterisk-right\"><label for='ff_1_names_last_name_' id='label_ff_1_names_last_name_' >Last Name<\/label><\/div><div class='ff-el-input--content'><input type=\"text\" name=\"names[last_name]\" id=\"ff_1_names_last_name_\" class=\"ff-el-form-control\" placeholder=\"Last Name\" aria-invalid=\"false\" aria-required=false><\/div><\/div><\/div><\/div><\/div><div class='ff-el-group'><div class=\"ff-el-input--label ff-el-is-required asterisk-right\"><label for='ff_1_email' id='label_ff_1_email' aria-label=\"Email\">Email<\/label><\/div><div class='ff-el-input--content'><input type=\"email\" name=\"email\" id=\"ff_1_email\" class=\"ff-el-form-control\" placeholder=\"Email Address\" data-name=\"email\"  aria-invalid=\"false\" aria-required=true><\/div><\/div><div class='ff-el-group'><div class=\"ff-el-input--label ff-el-is-required asterisk-right\"><label for='ff_1_subject' id='label_ff_1_subject' aria-label=\"Subject\">Subject<\/label><\/div><div class='ff-el-input--content'><input type=\"text\" name=\"subject\" class=\"ff-el-form-control\" placeholder=\"Subject\" data-name=\"subject\" id=\"ff_1_subject\"  aria-invalid=\"false\" aria-required=true><\/div><\/div><div class='ff-el-group'><div class=\"ff-el-input--label ff-el-is-required asterisk-right\"><label for='ff_1_message' id='label_ff_1_message' aria-label=\"Your Message\">Your Message<\/label><\/div><div class='ff-el-input--content'><textarea aria-required=\"true\" aria-labelledby=\"label_ff_1_message\" name=\"message\" id=\"ff_1_message\" class=\"ff-el-form-control\" placeholder=\"Your Message\" rows=\"4\" cols=\"2\" data-name=\"message\" ><\/textarea><\/div><\/div><div class='ff-el-group ' ><div class='ff-el-input--content'><div data-fluent_id='1' name='h-captcha-response'><div\n\t\tdata-sitekey='b6bae662-9dec-41b0-803c-bebe5a608ce0'\n\t\tid='fluentform-hcaptcha-1-1'\n\t\tclass='ff-el-hcaptcha h-captcha'><\/div><\/div><\/div><\/div><div class='ff-el-group ff-text-left ff_submit_btn_wrapper'><button type=\"submit\" class=\"ff-btn ff-btn-submit ff-btn-md ff_btn_style wpf_has_custom_css\"  aria-label=\"Submit Form\">Submit Form<\/button><\/div><\/fieldset><\/form><div id='fluentform_1_errors' class='ff-errors-in-stack ff_form_instance_1_1 ff-form-loading_errors ff_form_instance_1_1_errors'><\/div><\/div>            <script type=\"text\/javascript\">\n                window.fluent_form_ff_form_instance_1_1 = {\"id\":\"1\",\"settings\":{\"layout\":{\"labelPlacement\":\"top\",\"helpMessagePlacement\":\"with_label\",\"errorMessagePlacement\":\"inline\",\"cssClassName\":\"\",\"asteriskPlacement\":\"asterisk-right\"},\"restrictions\":{\"denyEmptySubmission\":{\"enabled\":false}}},\"form_instance\":\"ff_form_instance_1_1\",\"form_id_selector\":\"fluentform_1\",\"rules\":{\"names[first_name]\":{\"required\":{\"value\":false,\"message\":\"This field is required\",\"global\":false,\"global_message\":\"This field is required\"}},\"names[middle_name]\":{\"required\":{\"value\":false,\"message\":\"This field is required\",\"global\":false,\"global_message\":\"This field is required\"}},\"names[last_name]\":{\"required\":{\"value\":false,\"message\":\"This field is required\",\"global\":false,\"global_message\":\"This field is required\"}},\"email\":{\"required\":{\"value\":true,\"message\":\"This field is required\",\"global\":false,\"global_message\":\"This field is required\"},\"email\":{\"value\":true,\"message\":\"This field must contain a valid email\",\"global\":false,\"global_message\":\"This field must contain a valid email\"}},\"subject\":{\"required\":{\"value\":true,\"message\":\"This field is required\",\"global\":false,\"global_message\":\"This field is required\"}},\"message\":{\"required\":{\"value\":true,\"message\":\"This field is required\",\"global\":false,\"global_message\":\"This field is required\"}}},\"debounce_time\":300};\n                            <\/script>\n            \n            <\/div>\n        <\/div>\n    <\/section>\n\n<\/div>\n\n<script>\n    (function () {\n        var page = document.getElementById('erm-daf-sys');\n        if (!page) return;\n\n        var faqItems = page.querySelectorAll('.energycle-faq-accordion-item');\n        faqItems.forEach(function (item) {\n            var panel = item.querySelector('.energycle-faq-accordion-content');\n            if (panel) panel.setAttribute('aria-hidden', 'true');\n            var header = item.querySelector('.energycle-faq-accordion-header');\n            var icon = item.querySelector('.energycle-faq-accordion-icon');\n            if (!header || !panel || !icon) return;\n            header.addEventListener('click', function () {\n                var wasOpen = item.classList.contains('active');\n                faqItems.forEach(function (entry) {\n                    entry.classList.remove('active');\n                    var entryHeader = entry.querySelector('.energycle-faq-accordion-header');\n                    var entryPanel = entry.querySelector('.energycle-faq-accordion-content');\n                    var entryIcon = entry.querySelector('.energycle-faq-accordion-icon');\n                    if (entryHeader) entryHeader.setAttribute('aria-expanded', 'false');\n                    if (entryPanel) {\n                        entryPanel.setAttribute('aria-hidden', 'true');\n                        entryPanel.style.maxHeight = null;\n                    }\n                    if (entryIcon) {\n                        entryIcon.classList.remove('fa-minus');\n                        entryIcon.classList.add('fa-plus');\n                    }\n                });\n                if (!wasOpen) {\n                    item.classList.add('active');\n                    header.setAttribute('aria-expanded', 'true');\n                    panel.setAttribute('aria-hidden', 'false');\n                    panel.style.maxHeight = panel.scrollHeight + 'px';\n                    icon.classList.remove('fa-plus');\n                    icon.classList.add('fa-minus');\n                }\n            });\n        });\n    }());\n<\/script>\n\n<script type=\"application\/ld+json\">\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@graph\": [\n    {\n      \"@type\": \"Product\",\n      \"name\": \"Dissolved Air Flotation (DAF) System for Industrial Wastewater Treatment\",\n      \"description\": \"Industrial DAF system using micro-bubble flotation to remove suspended solids, emulsified oils, grease, and biological flocs from wastewater in plastic recycling, food processing, oil and gas, meat, paper, chemical, and industrial manufacturing applications.\",\n      \"image\": \"https:\/\/recycling.imgix.net\/image\/DAF\/Dissolved%20Air%20Flotation%20(DAF)-2.webp\",\n      \"brand\": {\n        \"@type\": \"Brand\",\n        \"name\": \"Energycle\"\n      },\n      \"manufacturer\": {\n        \"@type\": \"Organization\",\n        \"name\": \"Energycle\"\n      },\n      \"category\": \"Industrial wastewater treatment equipment\",\n      \"additionalProperty\": [\n        {\n          \"@type\": \"PropertyValue\",\n          \"name\": \"Flow capacity range\",\n          \"value\": \"10 - 100 m3\/h (custom larger systems available)\"\n        },\n        {\n          \"@type\": \"PropertyValue\",\n          \"name\": \"Saturation pressure\",\n          \"value\": \"400 - 600 kPa\"\n        },\n        {\n          \"@type\": \"PropertyValue\",\n          \"name\": \"Micro-bubble size\",\n          \"value\": \"20 - 70 \u00b5m\"\n        }\n      ]\n    },\n    {\n      \"@type\": \"FAQPage\",\n      \"mainEntity\": [\n        {\n          \"@type\": \"Question\",\n          \"name\": \"What removal rates can a DAF system achieve for TSS and FOG?\",\n          \"acceptedAnswer\": {\n            \"@type\": \"Answer\",\n            \"text\": \"When correctly paired with coagulation and flocculation chemistry, DAF systems typically achieve 95\u201399% TSS removal and similar FOG removal efficiency. Exact performance depends on influent characteristics, chemical dose, and recycle ratio.\"\n          }\n        },\n        {\n          \"@type\": \"Question\",\n          \"name\": \"Does DAF always require chemical pretreatment?\",\n          \"acceptedAnswer\": {\n            \"@type\": \"Answer\",\n            \"text\": \"For most industrial applications, coagulant and flocculant dosing significantly improves performance, especially on emulsified oils and fine suspended solids. Wastewater with complex contamination nearly always benefits from chemical conditioning upstream of the flotation cell.\"\n          }\n        },\n        {\n          \"@type\": \"Question\",\n          \"name\": \"How long does installation and commissioning take?\",\n          \"acceptedAnswer\": {\n            \"@type\": \"Answer\",\n            \"text\": \"Standard packaged units can be delivered and commissioned within a few weeks. Larger or custom-engineered systems have longer lead times confirmed during the engineering phase.\"\n          }\n        },\n        {\n          \"@type\": \"Question\",\n          \"name\": \"Can DAF handle variable flow rates and influent concentrations?\",\n          \"acceptedAnswer\": {\n            \"@type\": \"Answer\",\n            \"text\": \"Yes. PLC-controlled recycle ratio, chemical dosing, and skimmer speed allow the system to adapt to fluctuating loads. An equalization tank upstream further stabilizes the influent.\"\n          }\n        },\n        {\n          \"@type\": \"Question\",\n          \"name\": \"What information is needed to size a DAF system?\",\n          \"acceptedAnswer\": {\n            \"@type\": \"Answer\",\n            \"text\": \"Please provide peak and average wastewater flow rate, influent TSS, FOG, and BOD concentrations, pH and temperature range, effluent discharge standard or reuse target, available footprint, and whether an equalization or chemical dosing system is already in place.\"\n          }\n        },\n        {\n          \"@type\": \"Question\",\n          \"name\": \"Can treated water be reused in closed-loop washing lines?\",\n          \"acceptedAnswer\": {\n            \"@type\": \"Answer\",\n            \"text\": \"In many applications, such as plastic recycling and industrial washing, yes. DAF dramatically improves water stability by removing suspended solids and floatables, allowing for a high ratio of process water recirculation.\"\n          }\n        }\n      ]\n    }\n  ]\n}\n<\/script>\n\n\t\t<\/div>\n\t<\/div>\n\t\t<\/div>\r\n\t<\/div>\r\n<\/div>\r\n\r\n\r\n\t<\/div>\r\n\r\n<div class=\"vc_row-full-width vc_clearfix\"><\/div>\r\n\r\n\n\n\n<script type=\"application\/ld+json\">\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What is a dissolved air flotation (DAF) system in recycling?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"A DAF system removes fine suspended solids, oils, and micro-particles from recycling process water by injecting micro-bubbles of air. The bubbles attach to contaminant particles, floating them to the surface where a skimmer removes them as sludge. DAF is essential for water treatment and recirculation in plastic washing operations.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Why do recycling plants need DAF water treatment?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Recycling plants generate large volumes of contaminated wash water. DAF systems enable water recycling by removing suspended plastics, ink particles, oils, and organic matter to levels suitable for reuse. This reduces fresh water consumption by 80-90%, lowers discharge costs, and helps meet environmental permit requirements.\"\n      }\n    }\n  ]\n}\n<\/script>\n<\/div>","protected":false},"excerpt":{"rendered":"Industrial Wastewater Treatment Equipment Dissolved Air Flotation (DAF) System for Industrial Wastewater Treatment A dissolved air flotation system that separates suspended solids, emulsified oils, grease, and biological flocs from industrial wastewater using micro-bubble flotation. DAF is used in plastic recycling, food processing, oil and gas, meat and poultry, paper and pulp, chemical, and municipal sectors &hellip; <a href=\"https:\/\/www.energycle.com\/it\/sistema-di-flottazione-ad-aria-disciolta-daf\/\" class=\"more-link\">Continua a leggere <span class=\"screen-reader-text\">Sistema di flottazione ad aria disciolta (DAF)<\/span><\/a>","protected":false},"author":1,"featured_media":11461,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-11455","page","type-page","status-publish","has-post-thumbnail","hentry"],"_links":{"self":[{"href":"https:\/\/www.energycle.com\/it\/wp-json\/wp\/v2\/pages\/11455","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.energycle.com\/it\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.energycle.com\/it\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.energycle.com\/it\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.energycle.com\/it\/wp-json\/wp\/v2\/comments?post=11455"}],"version-history":[{"count":3,"href":"https:\/\/www.energycle.com\/it\/wp-json\/wp\/v2\/pages\/11455\/revisions"}],"predecessor-version":[{"id":18227,"href":"https:\/\/www.energycle.com\/it\/wp-json\/wp\/v2\/pages\/11455\/revisions\/18227"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.energycle.com\/it\/wp-json\/wp\/v2\/media\/11461"}],"wp:attachment":[{"href":"https:\/\/www.energycle.com\/it\/wp-json\/wp\/v2\/media?parent=11455"}],"curies":[{"name":"parola chiave","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}